The DCS button interface, 2-gang is used to implement a zero-voltage button signal on the Gira door communication BUS.
The DCS button interface has two mutually independent inputs for the connection of zero-voltage buttons.
The inputs can either be used for triggering a switching action (e.g. switching lights) via a switching actuator or flush-mounted switching actuator, or it can be assigned to a home station.
The DCS button interface is intended for installation in a device box behind a conventional button.
Technical data
Power supply:
via the 2-wire bus
Ambient temperature:
-5 °C to +50 °C
Notes
The button is connected via a 3.wire connection line which is approx. 20 cm long. This connection line can be extended to a maximum of 5 m.
If the button interface is assigned to a home station, the two inputs have differing functions: Input 1 triggers a floor call. This input is required when only a two-wire cable is available for connecting a home station including the floor-call button (e.g. when retrofitting an existing door intercom). Input 2 triggers a door call. This input is required when the automatic door opener of the home station is to be triggered via a mechanical button.
Dimensions in mm
W 43
H 28
D 15
Additional figures available in the media database
You will find figures of the selected products in the media database. You may use this figures for your publications. Please read the corresponding terms of use.